Switching Power Supply S-60

Switching Power Supply S-60
Switching Power Supply S-60
  • Categories:Single output series
  • MOQ:1
  • Brand:Trihero
  • FOB Port:Shanghai port, Ningbo port
  • Terms of Payment:Western Union, T/T, Paypal
  • Delivery Time:7 Working Days

Features: 
High efficiency, high reliability and low cost 
Switch input voltage range choice 
100% full load and machine test 
Protection characteristics: short circuit/overload
Air cooling 
Working frequency 37 KHz 
One year warranty 
Size:159*97*38mm(L*W*H)

model

S-60-5

S-60-12

S-60-15

S-60-24

S-60-48

output

Dc output voltage

5V

12V

15V

24V

48V

Output voltage tolerance

±2%

±1%

±1%

±1%

±1%

Rated output current

12A

5A

4A

2.5A

1.3A

Output current range

0-12A

0-5A

0-4A

0-2.5A

0-1.3A

Output power

60W

60W

60W

60W

62.4W

Ripple and the noise

120mVp-p

120mVp-p

150mVp-p

150mVp-p

200mVp-p

Dc voltage adjustable scope

+10, -5%

±10%

±10%

±10%

±10%

Start, rise, keep time

800ms,50ms,10ms/115VAC 300ms,50ms,80ms/230VAC

input

Input voltage range

85~264 VAC 47~63 Hz;120~370VDC

Exchange input current

2A/115 V 1A/ 230 V

efficiency

73%

76%

77%

79%

79%

Impulse current

Cold start current

30A/115VAC 60A/230VAC

Leakage current

<3.5 mA/240VAC

Protection characteristics

Overload protection

115%~165%

Protection way: current limiting, automatic recovery

Over-voltage protection

115%~135%

Protection way: hiccups, auto recovery mode

environment

Working temperature, humidity

-10℃~+60℃;20%~90 %RH

Keep temperature, humidity

-20℃~+85℃;10%~95 %RH

Vibrate resistance

10~500Hz,2G 10min./1 cycle time, 60 minutes, the axis

security

Compression sex

3: KVAC between input and output and input and output KVAC: 1.5 to 0.5: KVAC

Insulation resistance

Between the input and output, the input and output, and ground:
100M Ohms/500VDC

standard

Safety standards

Accord with
UL1012, UL1950,TUV EN60950

EMC standards

Accord with
EN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11;ENV50204,EN55024

other

weight

0.51Kg

packaging

30pcs/15.8Kg/0.99CUFT

note

1. All the parameters in has not specified, all is in 230 VAC voltage input, rated load and 25 ℃ conditions measuring income value.
2. Ripple and noise voltage is in 20 MHz bandwidth oscilloscope take 12 inches twisted pair end with 0.1 mu and 47 u when capacitance measurement.
3. Tolerance is voltage setting error, the voltage adjustment rate and adjust the sum total of the current rate.
4. The power to consider as a device installed in final equipment, this equipment must be to make sure it’s EMC index.
5. Specific output current see output drop forehead curve

30 W single output switching power supply,Appearance and installation sizeOutput derating characteristics,Static characteristics (24V)