Switching Power Supply SP-500

Switching Power Supply SP-500
Switching Power Supply SP-500
  • Categories:Single output series
  • MOQ:1
  • Brand:Trihero
  • FOB Port:Shanghai port, Ningbo port
  • Terms of Payment:Western Union, T/T, Paypal
  • Delivery Time:7 Working Days

Features:
High efficiency, high reliability
For AC power supply input global
100% full load and machine test
Protection characteristics: short circuit/overload/pressure
Built-in dc electric fan forced air cooling
Built-in fan switch control
Working frequency 110 KHz
PFC correction, built-in distance open/shutdown and voltage compensation signal interface
1 year warranty
Size: 170*120*93mm(L*W*H)

model

SP-500
-12

SP-500
-13.5

SP-500
-15

SP-500
-24

SP-500
-27

SP-500
-48

output

Dc output voltage

12V

13.5V

15V

24V

27V

48V

Output voltage tolerance

±1%

±1%

±1%

±1%

±1%

±1%

Rated output current

40A

36A

32A

20A

18A

10A

Output current range

0-40A

0-36A

0-32A

0-20A

0-18A

0-10A

Output power

480W

486W

480W

480W

486W

480W

Ripple and the noise

240mVp-p

240mVp-p

240mVp-p

240mVp-p

200mVp-p

300mVp-p

Dc voltage adjustable scope

-16%,+10%

-12%,+15%

-10%,+20%

-16%,+10%

-12%,+11%

-15%,+16%

Start, rise, keep time

1.5s,50ms,20ms Loaded with

input

Input voltage range

88~264 VAC 47~63 Hz;124~370VDC

Power factor

PF>0.95/230VAC PF>0.95/115VAC Loaded with

Exchange input current

7A/115 V 3.5A/ 230 V

efficiency

81%

82%

83%

85.5%

86.5%

87%

Impulse current

18A/115V 36A/230V

Leakage current

<3.5mA/240VAC

Protection characteristics

Overload protection

105%~135%

Protection way: current limiting, automatic recovery

Overvoltage protection

115%~135%

Protection way: hiccups, auto recovery mode

environment

Working temperature, humidity

-10℃~+50℃;20%~90 %RH

Keep temperature, humidity

-20℃~+85℃;10%~95 %RH

Vibrate resistance

10~500Hz,2G 10min./ 1 cycle time, 60 minutes, the axis

security

Compression sex

3: KVAC between input and output and input and output KVAC: 1.5 to:
0.5KVAC

Insulation resistance

Between the input and output, the input and output, and ground:
100M Ohms/500VDC

standards

Insulation resistance

Accord with
UL1950,TUV EN60950

EMC standard

Accord with
EN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11;ENV50204

other

weight

1.9Kg

packaging

10pcs/19.5kg/1.22CUFT

note

  1. All the parameters in has not specified, all is in 230 VAC voltage input, rated load and 25 ℃ conditions measuring income value.

  2. Ripple and noise voltage is in 20 MHz bandwidth oscilloscope take 12 inches twisted pair end with 0.1 mu and 47 u when capacitance measurement.

  3. Tolerance is voltage setting error, the voltage adjustment rate and adjust the sum total of the current rate.

  4. The power to consider as a device installed in final equipment, this equipment must be to make sure it’s EMC index.

  5. Specific output current see output drop forehead curve.

500 W single output switching power supply, Appearance and installation sizeOutput derating characteristics,Derating curve of output to input voltage